Gear Flow Meters in Cartridge Design (ZHM-CT)
The gear flow meter sin cartridge design were mainly developed for the automotive industry. Construction characteristics as flat seals and single-ended shafts guarante ideal purging qualities.
As an option adapter plates can be supplied.
Specification:
- Measuring range: 0.005…3 l/min
- Viskosity: 5…25,000 mm²/s
- Linearity: ±0.5 % of actual value
- Pressure: max. 400 bar
- Fluid temperature: max. +180 °C
Advantages:
- The cartridge design reduces the weight by another 50% compared with its predecessor. Therefore, the Cartridge-ZHM may be installed right behind the spray gun without adverse effects on the dynamic properties of the spray robot.
- The newly designed measuring kit provides a high resolution and allows for a precise measurement over a measuring range which would usually require two flow meters.
- The new flow meters can be completely purged within a few seconds and rapid colour changes are possible with no adverse effects on paints by residual sediments.
- The integral carrier-frequency pulse amplifier type VTE.CT or fibre-optic amplifier type FOP 60 allow for space-saving installation.
- A legal protection of registered design for the Cartridge-cear floe meter has been applied for.
Here you can find our Pickups and Amplifiers as well as our Evaluation Electronics.