Gear Flow Meters in Cartridge Design (ZHM-CT)

The gear flow meter sin cartridge design were mainly developed for the automotive industry. Construction characteristics as flat seals and single-ended shafts guarante ideal purging qualities.

As an option adapter plates can be supplied.

Specification:

  • Measuring range: 0.005…3 l/min
  • Viskosity: 5…25,000 mm²/s
  • Linearity: ±0.5 % of actual value
  • Pressure: max. 400 bar
  • Fluid temperature: max. +180 °C

Advantages:

  • The cartridge design reduces the weight by another 50% compared with its predecessor. Therefore, the Cartridge-ZHM may be installed right behind the spray gun without adverse effects on the dynamic properties of the spray robot.
  • The newly designed measuring kit provides a high resolution and allows for a precise measurement over a measuring range which would usually require two flow meters.
  • The new flow meters can be completely purged within a few seconds and rapid colour changes are possible with no adverse effects on paints by residual sediments.
  • The integral carrier-frequency pulse amplifier type VTE.CT or fibre-optic amplifier type FOP 60 allow for space-saving installation.
  • A legal protection of registered design for the Cartridge-cear floe meter has been applied for.

Here you can find our Pickups and Amplifiers as well as our Evaluation Electronics.

Downloads