Dispense Control Device (DCD)
The Dispense Control Device (DCD) – a metering gear pump with integral flowmeter for reliable dispensing.
The CDC was designed in cooperation with the Swiss pump manufacturer POMTAVA. It includes a metering gear pump with an integral flowmeter and guarantees for a reliable dispensing of paints and PU components.
Specification Metering Gear Pump:
- Sealing: Lip seal and liquid barrier
- Rotation speed: clockwise rotation (A)
- Output pressure: max. 15 bar
- Input / Output: 2 bores _6 mm on the pump body
- Delivery with block G1/4”
- Driving shaft diameter: _12 mm key, H=40 mm
- Weight: approx. 2,5kg
Specification Gear FlowMeter ZHM 01/1 P1.F.1
- Dispensing range: 0,005 to 2 l/min
- Accuracy: ±0,7 % of actual value
- Repeatability: 0,1 %
- Pulse rate: ca. 26.500 pulses/ltr.
- Operating pressure: max. 40 bar
- Materials:
- Body: 1.4305
- Gears: 1.4122 (TiN-coated)
- Seals: FLD-PTFE
- Bearings / shafts: thungsten carbide
Advantages:
- Excellent purging qualities
- no hose connection for seperate flowmeter
- Minimum pressure loss
- Short response time
- Compact design
- Space-saving installation
- Cost savings
- Ideally for fully automated systems
Here you can find more information about our cooperation partner Pomtava.