Welcome to KEM -

Your Partner for Flow Measurement and Control

  • Language Selection

Local Converters (WIE)

programmable and with interface

The converters are passive 4 - 20 mA sensors with inductive input stage. Both analogue and frequency output can be linearized with up to 10 points.

The inductive converters are recommended for higher medium temperatures up to +350 °C [+662 °F].

The integral interface and the KEM EasyControl software allow for free programming.

 

Technical Data

  • Output Signal: 4 - 20 mA, 2-wire (passive)
  • Supply Voltage: 12 - 30 V, regulated
  • Frequence Range: 1 up to 5,000 Hz depending on flow meter
  • Allowable Load: 20 mA, max. 800 Ω
  • Response Time: 250 ms (for input frequencies > 7 Hz)
  • Ambient Temperature: -40 °C up to +70 °C [-40 °F up to +158 °F]
  • Medium Temperature: -20 °C up to +350 °C [-4 °F up to +662 °F]

 

Evaluation Electronics

   

Downloads