with single pickup, for screwing in for all KEM flow meters
Our ECO Pulse Amplifiers can be equipped with all KEM volume meters. The amplifier system includes a single tap with temperature range up to +150 °C and double tap for higher resolutions or bi-directional flow measurement with standardized push-pull output stage.
Compact Design for volume meters Medium temperatures up to +150 °C [+302 °F] Frequency doubling Detection of the flow direction EMC Directive 2014/30/EU compliant
Functions & Specifications
Supply Voltage
+12 up to 27 V DC, regulated
Quiescent Current
< 20 mA
Frequence Range
1 up to 5,000 Hz
Ambient Temperature
-40 °C up to +60 °C [-40 °F up to +140 °F]
Medium Temperature
-40 °C up to +150 °C [-40 °F up to +302 °F], depending on version
Output Signal
1:1-frequency or direction signal & double frequency
Ingress Protection
IP 65
Pickups, Amplifiers, Evaluation Electronics and Additional Accessories