TRICOR Coriolis mass flow meters for liquids and gases

Features & Benefits

  • Robust, no moving parts
  • Customized installation length
  • Excellent repeatability (better than ±0.05 %), accuracy (±0.1 %)
  • Advanced transmitter technology
    Upgrade/modernize in place
  • Increased productivity
  • Considerable cost savings for installation
  • Increased product quality
  • Optimized lifecycle management

Functions & Specifications

Flow Rate

Mass Flow Rate (max.): 28,000 kg/h [1,029 lb/min]
Volumetric Flow Rate (max.): 28,000 l/h [123.3 gpm, 4,227 oil bbl/d (US)]
Nominal Meter Size: DN25 [1”]

Pressure Rating

100 bar [1,450 psi]

Accuracy (Liquids)

Basic Accuracy (Mass Flow): ±0.1 % of flow rate
Repeatability (Mass Flow): better than ±0.05 % of flow rate
Basic Accuracy (Volume Flow): ±0.15 % of flow rate
Repeatability (Volume Flow): better than ±0.05 % of flow rate
Zero Stability: ±0.01 % of full scale

Accuracy (Gases)

Basic Accuracy (Mass Flow): ±0.5 % of flow rate
Repeatability (Mass Flow): ±0.25 % of flow rate

Density

Density Range: up to 2,500 kg/m3 [2.5 g/cm3]
Density Accuracy: ±1.0 kg/m3 [±0.001 g/cm3]
Density Repeatability: ±0.5 kg/m3 [±0.0005 g/cm3]

Temperature

Process Temperature Range: -60 °C ... +200 °C [-76 °F ... +392 °F]
Temperature Accuracy: ±1 °C ±0.5 % of reading [±1.8 °F ±0.5 % of reading]
Temperature Repeatability: ±0.2 °C [±0.36 °F]

Materials (Wetted Parts)

Tubes: 1.4404 [AISI 316L]
Case: 1.4404 [AISI 316L]
Flow Splitter: CF3M [AISI 316L]
Brazing Alloy: BNi-2

Pickups, Amplifiers, Evaluation Electronics and Additional Accessories

TRICOR Coriolis Transmitter – CLASSIC Series – TCE 6000
TRICOR Coriolis Evaluation Electronics
CLASSIC Series
TRICOR Coriolis

TCE 6000

TRICOR Coriolis transmitter in compact version without local display

View specification
TRICOR Remote Display – CLASSIC Series – TRD 8001
TRICOR Coriolis Evaluation Electronics
CLASSIC Series
TRICOR Coriolis

TRD 8001

TRICOR Coriolis remote display - up to 1,000 m from the mass flow meter

View specification
TRICOR Coriolis Transmitter – CLASSIC Series – TCE 8000 Panel Mount
TRICOR Coriolis Evaluation Electronics
CLASSIC Series
TRICOR Coriolis

TCE 8000 Panel Mount Housing

TRICOR Coriolis Transmitter in Panel Mount Housing for Flow, Density and Temperature

View specification
TRICOR Coriolis Transmitter – CLASSIC Series – TCE 8000/8100 Remote
TRICOR Coriolis Evaluation Electronics
CLASSIC Series
TRICOR Coriolis

TCE 8000/8100 wall mounting

TRICOR Coriolis transmitters in separate version for flow, density and temperature

View specification
TRICOR Coriolis Transmitter – CLASSIC Series – TCE 8000/8100 Compact
TRICOR Coriolis Evaluation Electronics
CLASSIC Series
TRICOR Coriolis

TCE 8000/8100 Compact

TRICOR Coriolis transmitters in compact design for flow, density and temperature

View specification

Documents, Manuals & Software

TitleDateLanguageDownload
TRICOR Coriolis Mass Flow Meter - PRO Series - Datasheet01.01.2022English (EN)PDF (3 MB)
TRICOR Coriolis Mass Flow Meters – PRO Series – Manual02.11.2022English (EN)PDF (5 MB)
Back to top